2.10 240V AC Wiring GuideLink
Mains powered pumps must be wired by a qualified electrican.
This guide is offered as a basic suggestion only. Subject to the pump type, and circuit control requirements modifications to this concept drawing may be required.
2.10.1 Overview DiagramLink
2.10.2 Parts ListLink
Number | Item | Brand | Part Number Suggested |
Vendors |
---|---|---|---|---|
1 | Power Supply | Meanwell | HDR-30-12 | Jaycar |
2 | Relay | Weidmuller | DRI-SERIES 1CO 12A | Tro Pacific |
2b | 12V DC Coil | Weidmuller | DRI-SERIES 12VDC 1CO 10 AMP* | Tro Pacific |
3 | Contactor | Hager | ECS-225 | CNW, MMEM, Haymans |
4 | Pump Motor | Various | 240V AC 10Amps | N/A |
*note: Optional - WITH LED, FREE-WHEEL DIODE AND TEST BUTTON
2.10.3 24V SupplyLink
In some cases it may be more convenient to use a 24V DC power supply and relay combination.
Be aware that when a 24V power supply is used, the Level Probe will then be 24V DC Power
2.10.4 Power supply currentLink
The current requirements of the Power Supply will largely be driven by the circuit. In many cases 1.5A is suitable to power the Fuellox equipment.